Warranty claim
Product information
Serial number
25472371
TSM invoice number
1387
Product model
ARIA 240 Super Hydro - with charger
Delivery note date
03/12/2025
Registered on
25/06/2026
Guarantee applicant name
ZISIS
Guarantee applicant surname
ZIOGAS
Fault description
Fault date
25/06/2026
Working hours
5
Fault description
During the machine demonstration, we found that the automatic filter cleaning was not functioning. Although the air compressor was operating, it was not collecting a sufficient amount of air to perform the discharge and clean the filter. We determined that the fault was due to the timer and its solenoid valve. We ordered the spare parts, installed them, and the machine is now operating normally.
Part number requested under warranty
Part number
15-6000-002
Quantity
1
Part number
15-3511-011
Quantity
1
Status
Request status
Closed